Sold listing | Number of views: 8

Plot for sale - Commercial-building plot in the heart of Gowino!

15 € / m2

Price 12 274 €

9 photos
Sold
Agent of the Month — May
Price 12 274 €
Price per m2 15 €
Area 837 m2
Market secondary
Locality

Details Properties.

Financial information

Price 12 274 €
Price per m²15 €
Area837 m2

Location

General information

Offer number32453223
Marketsecondary
Conditionother

Technical details

Building typeany
BasementYes
Storage roomYes
GardenYes

Description Properties.

For sale is a plot of land measuring 837 m2 located in Gowinie on Ulicy Akacjowej. The area has all commercial and service facilities within reach.

The property is covered by the local spatial development plan:
Single-family detached residential development areas.

Access to the plot is paved, the neighborhood is quiet.

Site card from the current spatial development plan:

11.MN
1)
Land use purpose:
a)
primary land use: single-family detached residential development areas;
b)
service function (non-hazardous activity) in a residential building up to 30% of the building's total floor area is permitted, with nuisance levels and noise adapted as for single-family residential development.
2)
General urban conditions:
a)
part of the land is located in a conservation protection zone (plots no. 48/14, 48/15, 48/22, 50/10, 50/11, 50/12, 50/14, 50/15, in accordance with Annex No. 1 to the resolution);
b)
single-family detached residential development, one residential building per one building plot;
c)
building orientation with the main ridge parallel to the road edge (in case the plot is located at the junction of two roads, the building orientation with the main ridge should be parallel to the edge of the higher category road);
d)
preservation of existing buildings that do not comply with the plan provisions is permitted; when expanding the aforementioned buildings – new elements must comply with the plan provisions;
e)
subdivision into new building plots with an area of not less than 1,000 m2, the proposed subdivision is presented in Annex No. 1 to this resolution;
f)
minimum plot area for which building construction is permitted – 1,000 m2;
g)
the minimum building plot area does not apply to building plots existing as of the date of the plan adoption;
h)
subdivision of larger plots is permitted;
i)
subdivision of internal roads within the area as necessary access roads to properties with a minimum width of 6.0 m is permitted;
j)
required parking spaces resulting from the investment program should be provided within the property: not less than 1 space/1 dwelling; in case of service introduction - not less than 3 spaces;
k)
on plots no. 145/5 and 144/8, land development and new residential construction is permitted after carrying out necessary reclamation works consisting of land drainage and clearing of existing reclamation ditches;
3)
Building development indicators:
a)
main building as a detached structure;
b)
construction of an auxiliary building connected to the main building or as a detached structure is permitted;
c)
building coverage ratio: maximum 40%;
d)
building intensity: from 0.2 to 0.5;
e)
allowable height of the main building measured from ground level at the main entrance to the building to the highest point of the main building's ridge, maximum 9.0 m;
f)
allowable height of auxiliary building measured from ground level at the main entrance to the building to the highest point of the auxiliary building's ridge, maximum 6.0 m;
g)
building basement is permitted provided that geotechnical soil testing is carried out;
h)
maximum allowable height of the ground floor level: 0.6 m;
i)
allowable number of stories for all buildings: maximum 2 above-ground stories including usable attic;
j)
allowable roof types: roofs with symmetrical roof slopes;
k)
for residential construction located within the conservation protection zone, only gabled, intersecting gabled and hip roofs are permitted;
l)
allowable roof slope angles for the main building: 30° – 45° or 22° on a knee wall with a height of 0.5 to 1.2 m;
m)
allowable roof slope angles for auxiliary and service buildings: 22° – 45°;
n)
roof covering type: the same type of roof covering must be used for the entire property. Ceramic or concrete tiles or similar materials in shades close to red, brown or graphite are required;
o)
non-crossing building lines at a distance of 6.0 m from the boundary lines with access roads, in accordance with Annex No. 1 to this resolution;
p)
non-crossing building lines at a distance of 6.0 m from the boundary lines with internal roads, in accordance with Annex No. 1 to this resolution;
q)
other non-crossing building lines (including building line for new residential construction at a distance of 50.0 m from the cemetery area), in accordance with Annex No. 1 to this resolution;
r)
protection zone at a distance of 5.0 m from the axis of the overhead medium voltage power line in each direction; in case of network reconstruction in the form of underground cable, protection zones cease to apply;
s)
biologically active area: minimum 60%.

Floor plans Properties.